Change Your Working Key
How to Reset a Kwikset SmartKey Lock
Call (771) 240-1484 for a Kwikset SmartKey reset if your current key no longer turns; we provide mobile lock rekeying and repair. If your key works, the steps below show you how to change the key your lock accepts.
- We come to you
- Open 24/7
- 1-year warranty on parts and labor
What a Kwikset SmartKey Reset Requires
- A key that operates this lock — Start with the current working key, not just a key that slides into the opening. It must turn the cylinder before you begin. These owner steps change the accepted key; they do not restore a cylinder when neither key works.
- A compatible replacement key — Have the new key beside you before removing the current one. Choose a compatible key with clean, unworn cuts. A worn key or an inaccurate copy can cause trouble during rekeying or leave its duplicates unable to operate the lock.
- The original supplied rekeying insert — Locate the thin rekeying insert supplied with your SmartKey lock. You will place it in the small opening beside the keyway while the working key holds the cylinder in position. Do not substitute another household object or force anything into that opening.
- Preparation for your specific lock — These instructions rekey the mechanical cylinder; keypad programming is a separate process. For models with different preparation requirements, check the manual through Kwikset support. Electronic models with automatic locking can require battery removal before rekeying.
Rekey Your Kwikset SmartKey Cylinder With the Working Key
- Hold the door fully open — Keep the lock installed and prevent the door from swinging shut. Extend a deadbolt into its locked position while the door stays open; put a knob or lever lock in its locked position.
- Turn the current key clockwise — Insert the working key completely. Turn it 90 degrees clockwise, a quarter turn, and leave it there. Measure the turn from its starting position rather than guessing from the key’s appearance.
- Insert and withdraw the supplied insert — Push the supplied rekeying insert fully and firmly into the small opening beside the keyway. A small click can accompany insertion. Withdraw the insert, then remove the current key without rotating the cylinder.
- Seat the new key completely — Slide the replacement key all the way in. Its shoulder—the wider edge where the cut section ends—must meet the cylinder face. Keep it fully seated throughout the next turns.
- Turn the new key counterclockwise — Rotate the new key 180 degrees counterclockwise, a half turn. Turn without pushing, pulling or tilting the key; changing its depth during this movement can program the cylinder incorrectly.
- Turn clockwise and check retention — Rotate the key 180 degrees clockwise to return to the previous position. Gently pull straight outward. The key must stay in the cylinder at this checkpoint; stop if it comes out.
- Return to the starting position — Turn the retained key 90 degrees counterclockwise, back to the original starting position. Remove it there. Do not force removal from a different position.
- Test both keys before closing — Reinsert the new key and operate the lock with the door open. Check that the old key no longer operates it, then test any copies of the new key. Retract the deadbolt before closing the door.
Need help now? (771) 240-1484
Why a Kwikset SmartKey Reset Leaves the Key Stuck
The new key was not fully seated
A partly inserted key can leave the cylinder programmed to the wrong key position. If the fully inserted new key will not turn afterward, stop and arrange professional help rather than forcing it.
The key moved inward or outward
Pushing, pulling or tilting the key during rotation can disrupt rekeying even if you initially inserted it completely. Keep the door open if neither key operates the cylinder after the attempt.
The replacement key is worn or poorly copied
Kwikset identifies worn cuts and inaccurate copies as causes of rekeying problems. One working key does not prove its duplicates work, so test each copy before relying on it for entry.
The key came out during the retention test
Removal at the checkpoint in step six means the rekeying test failed. Do not close the door and treat the lock as finished; a key that turns but pulls out at the wrong position still needs attention.
When Your Kwikset SmartKey Cylinder Needs Professional Help
Stop owner rekeying if the current key is missing, neither key turns after an attempt, or the new key fails the retention test. We provide Kwikset SmartKey rekeying and repair, with lock rekeying from $14 and lock repair from $35. Call (771) 240-1484 or contact us, and identify whether the problem began before or during rekeying. DC Lock N Key comes to your door, so leave a failed cylinder undisturbed while arranging service.
Need help now? (771) 240-1484
Frequently asked questions
Can I reset my SmartKey lock without the current working key?
The owner rekeying procedure requires a key that currently turns the cylinder. A key that merely fits is insufficient. If you have lost every working key, we provide mobile locksmith service rather than asking you to attempt this sequence.
Will rekeying SmartKey remove my keypad access codes?
Rekeying changes which physical key operates the mechanical cylinder. It does not delete keypad access codes. If your goal is to remove someone’s access completely, address their keypad code separately as well as their physical key.
Do I need to replace the whole lock when someone keeps an old key?
A successful SmartKey rekey changes the accepted key so the previous key no longer operates that cylinder. An unreturned key alone does not require replacing the entire lock. If the lock also sticks or fails its tests, we offer both lock repair and lock change services.
Can I make several SmartKey locks use the same key?
Compatible SmartKey cylinders can be rekeyed individually to the same suitable key. You need a working key for each cylinder before starting its rekeying sequence. Test the shared key in every lock; changing one cylinder does not change the others.
SmartKey Reset Failed? Keep the Door Open
Stop if neither key turns or the retention test fails. Call (771) 240-1484 for mobile lock rekeying or repair.